    Dear Ken, As per my experience, BN 3500 can be connected to Controllogix PLC through Controlnet network only, so it is not possible to get BN 3500 talk to Controllogix PLC using Ethernet/IP protocol. To get BN 4500 connected to Controllogix, here are what you need: - RSLogix 5000 - RSNetworx for controlnet - RSLinx - Field Monitor Configuration Software for RSLogix 5000 - EDS files for BN 3500 - Controllogix PLC with Controlnet module (1756-CNB/CN2) instead of 1756-ENBT Alternative way to get BN 3500 connected to Controllogix PLC is utilize Modbus serial port of BN-3500. This option need modbus module (Prosoft MVI56-MCM or other brand) to be installed on controllogix.

    NevadaBently Nevada 1701 Software

    Bently Nevada 1701 Software

    Hope this help Ikhtiander. A quick look at the description of this module says it is a Modbus/TCP device.

    I am not sure if you are asking if the RSLogix5000 software can communicate with the BN module or if the Controllogix PLC can. I do not believe either can directly, although my understanding is that you can now control the TCP/IP messages from within the Controllogix PLC version 20 or better so that you can do this if you write the code yourself. It seems very messy to me. The other option is to buy a Modbus/TCP module for your controllogix PLC. You have clicked on the '?' Button for search help.

    To search the site, enter your search terms in the box labeled 'search the site' and hit Enter. Some tips for better search results. Precede each search term with a '+', as follows:. +Modbus +TCP Otherwise, any post with either term will match.

    Use double quotes around phrases, as follows:. +'Allen Bradley' +ethernetOtherwise, posts containing these words in separate locations will match. To exclude a word, precede it with a '-', as follows:. +Modbus -Plus This will return only posts containing 'Modbus' but NOT containing 'Plus'.

    Note that common words (and, that, etc.) and words shorter than 2 characters are automatically excluded from searches. Select the categories for which you would like to see messages displayed. Applications Application Questions and Problems Automation Business The Business of Automation and Control Communications Communications systems and equipment. Engineering Engineering and workplace issues. HMI Human-Machine Interface and SCADA. Information Information resources, documentation.

    Languages Programming languages. Motion Control Motion control, servos, steppers, etc. Networking Local and wide area networking in factory automation. Open Control Open interfaces, software and hardware PCs in Automation Computers in manufacturing; also hardware discussion. PLCs PLCs and related questions.

    Power Generation Power generation equipment control. Process Control Continuous process industries, DCS questions. Sensors Sensor technologies. Software in Automation Software, including programming, OS issues, etc.

    Plcforum.uz.ua:: View topic - Request Bently Nevada 1701/02-XX software - RSLogix5000 plcforum.uz.ua Request Bently Nevada 1701/02-XX software - RSLogix5000 Page 1 of 1 Author: nu6120ho Mon Aug 24, 2009 6:35 am Post subject: Request Bently Nevada 1701/02-XX software - RSLogix5000 Dear All, I need in FieldMonitor Bently Nevada 1701/02-xx software which compatible for RSLogix 5000. If somebody could post it then I would be very gratefull. Thanks in advance. Page 1 of 1 All times are UTC + 3 hours Powered by phpBB® Forum Software © phpBB Group http://www.phpbb.com/.

Designed by Tistory.